Ampro Testing Machines
Ampro Testing Machines
Naraina, New Delhi, Delhi
GST No. 07ABCPY9668B1Z7
TrustSEAL Verified
Call 0804898782788% Response Rate
SEND EMAIL

UREA DOSER TESTER

Pioneers in the industry, we offer urea dozer pump test bench and scr doser testing machine from India.

Urea Dozer Pump Test Bench

Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
  • Urea Dozer Pump Test Bench
Get Best Quote
Approx. Price: Rs 1.29 Lakh / SetGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
BrandAMPRO
Voltage220V AC
Weight5 KG
Carton BoxYes
Country of OriginMade in India
Model Name/NumberAMPRO UREA DOSER TESTER
Usage/ApplicationAutomobile
MaterialSteel

1. Main interface

  • Interface can select urea pump, sensor, system settings, online upgrade, user manual functions
  • Urea pump model selection interface, you can choose different urea pumps for testing
  • Sensor selection interface, different sensors can be selected for testing

2. Urea pump test

  1. Functional testing
  1. Standby -

Urea pump will stop function test in standby mode

  1. Pre injection pressure build-up -

After clicking the "pre-injection pressure" button, the SCR controller will carry out the operation of air evacuation and pressure establishment in the pipeline.

  1. Clean (purge) -

After testing, before dismantling the urea pipeline, you need to click the "Clean (Purge)" button. The SCR controller will control the urea pump to perform the cleaning operation, and the urea pump and urea solution in the pipeline will be purged into the urea box.

  1. Large/Medium/Small Flow Injection -

After successful pressure building, click "large flow injection", "medium flow injection" and "small flow injection" to observe the injection of urea solution.

  1. Component testing
  • Component testing can only be done in standby mode
  1. Message hint
  • Display error, warning, prompt and fault information, etc.

3. Nitrogen and Oxygen Sensor Testing

  1. After connecting the oxynitride sensor, click the "Start" button to start the test. Nitrogen and oxygen sensors will be heated first. After about one minute, they will be heated to a certain temperature and stop heating. The oxygen concentration and nitrogen oxide concentration around the sensor will be measured. The whole testing process is 5 minutes.
  1. Whether the nitrogen and oxygen sensor is damaged or not can be judged according to the measured "oxygen concentration (%)" and "NO x (ppm)". In air environment, the oxygen concentration is about 20%, and the range of NO x ppm is 0-30.

4. Measurement of Liquid Level/Temperature Sensor

  1. The liquid level and temperature sensor are used to measure the resistance value of the sensor, and then convert it into urea temperature and liquid level height.
  2. When testing the liquid level sensor, the sensor can be removed from the urea box and slid the float manually. At the same time, whether the liquid level resistance changes or not can be observed.

5.Testing of Exhaust Temperature Sensor

  1. The detection of the temperature sensor is also to test the resistance of the sensor, and then convert the resistance value to the temperature value according to the type of sensor.
  2. Currently supports 3 types of temperature sensors: PT100, PT200, PT1000

6. System setup

  1. Android version software connects SCR controller via Bluetooth Bluetooth connection steps:
  2. Click the "Scan" button to scan peripheral Bluetooth devices
  3. After selecting the device in the Bluetooth device list, click the Connection Button. For the first pairing, you need to input PIN code (1234)
  4. Windows version software connects SCR controller via USB cable or Bluetooth

7.Online upgrade

Request
Callback


Additional Information:

  • Item Code: AMPRO_SCR_TEST_BENCH
  • Production Capacity: 100
  • Delivery Time: 7-15 Days
  • Packaging Details: Metal Body
Yes! I am interested

SCR DOSER TESTING MACHINE

SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
  • SCR DOSER TESTING MACHINE
Get Best Quote
Approx. Price: Rs 1.3 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Usage/ApplicationCommercial
Model Name/NumberAMPRO DOSER TESTER
Digit Display SizeColour Display
Country of OriginMade in India
BrandAMPRO

1. Main interface
  • Interface can select urea pump, sensor, system settings, online upgrade, user manual functions
  • Urea pump model selection interface, you can choose different urea pumps for testing
  • Sensor selection interface, different sensors can be selected for testing

2. Urea pump test

  1. Functional testing
  1. Standby -

Urea pump will stop function test in standby mode

  1. Pre injection pressure build-up -

After clicking the "pre-injection pressure" button, the SCR controller will carry out the operation of air evacuation and pressure establishment in the pipeline.

  1. Clean (purge) -

After testing, before dismantling the urea pipeline, you need to click the "Clean (Purge)" button. The SCR controller will control the urea pump to perform the cleaning operation, and the urea pump and urea solution in the pipeline will be purged into the urea box.

  1. Large/Medium/Small Flow Injection -

After successful pressure building, click "large flow injection", "medium flow injection" and "small flow injection" to observe the injection of urea solution.

  1. Component testing
  • Component testing can only be done in standby mode
  1. Message hint
  • Display error, warning, prompt and fault information, etc.

3. Nitrogen and Oxygen Sensor Testing

  1. After connecting the oxynitride sensor, click the "Start" button to start the test. Nitrogen and oxygen sensors will be heated first. After about one minute, they will be heated to a certain temperature and stop heating. The oxygen concentration and nitrogen oxide concentration around the sensor will be measured. The whole testing process is 5 minutes.

 

  1. Whether the nitrogen and oxygen sensor is damaged or not can be judged according to the measured "oxygen concentration (%)" and "NO x (ppm)". In air environment, the oxygen concentration is about 20%, and the range of NO x ppm is 0-30.

4. Measurement of Liquid Level/Temperature Sensor

 

  1. The liquid level and temperature sensor are used to measure the resistance value of the sensor, and then convert it into urea temperature and liquid level height.
  2. When testing the liquid level sensor, the sensor can be removed from the urea box and slid the float manually. At the same time, whether the liquid level resistance changes or not can be observed.

5.Testing of Exhaust Temperature Sensor

 

  1. The detection of the temperature sensor is also to test the resistance of the sensor, and then convert the resistance value to the temperature value according to the type of sensor.
  2. Currently supports 3 types of temperature sensors: PT100, PT200, PT1000

6. System setup

 

  1. Android version software connects SCR controller via Bluetooth Bluetooth connection steps:
  2. Click the "Scan" button to scan peripheral Bluetooth devices
  3. After selecting the device in the Bluetooth device list, click the Connection Button. For the first pairing, you need to input PIN code (1234)
  4. Windows version software connects SCR controller via USB cable or Bluetooth

7.Online upgrade 

Request
Callback
Yes! I am interested
X

Product Videos

Watch More Videos

Explore More Product

View All Product




Reach Us
Manoj Kumar Yadav (CEO)
Ampro Testing Machines
CB-152, 2nd Floor, Ring Road, Naraina
New Delhi - 110028, Delhi, India


Call Us


Send E-mail